Offer request

My Fruit Advanced

“Big plans? No problem.”

My Fruit Advance opens the software to a different level of storage. This module enables the full integration of refrigeration, including machine room, and CA. But it offers much more: ACR1.0, measurement of ethylene including production, respiration. The system can manage up to 56 rooms and 200 Palliflex units.

  • Basic configuration
  • Max. number of stores (AUS)
  • Max. number of ACR stores32
  • Max. number of rooms (central)56
  • Max. number of measuring stations2
  • Max. number of Palliflex units 200
  • Max. number of CO2 absorbers 8
  • Max. number of (V)PSA’s 4
  • C2 H4 removal controlled by My Fruit
  • Max. number of C2 H4 decomposers 8
  • ACR module activation possible 1.0
  • Measurement and injection of gases
  • Measurement and registration of O2 and CO2
  • O2 meter 0-2.5% range
  • O2 meter 0-25% range
  • Number of CO2 ranges 2
  • Measurement and registration of C2 H4
  • Extra sensors (including alarm/output) 15
  • CO2 absorption based on chalk
  • CO2 injection
  • C2 H4 injection
  • Aeration based on CO2 value
  • Temperature control
  • Max. number of temperature sensors per room 6
  • Rending in °F
  • Refrigeration control in cold stores
  • Max. number of relay groups refrigeration 9
  • Machine room refrigeration controlled
  • Control of refrigeration machine room possible1
  • Relative humidity measurement
  • Control of suction pressure
  • Defrosting sensors
  • Pilot temperature sensor
  • Extras that make the difference
  • Moisture loss measurement and registration
  • Relative humidity measurement
  • Central measurement and registration of NH3
  • Automatic room leakage test
  • CA flex: programmable conditions
  • My Fruit APP
  • Basic configuration
  • Max. number of stores (AUS)16
  • Max. number of rooms (central)82856112
  • Max. number of measuring stations1124
  • Max. number of Palliflex units 20100200400
  • Max. number of CO2 absorbers 14810
  • Max. number of (V)PSA’s 12410
  • C2 H4 removal controlled by My Fruit
  • Max. number of C2 H4 decomposers 14810
  • ACR module activation possible 1.01.0 / 2.0
  • Max. number of ACR stores3264
  • Measurement and injection of gases
  • Measurement and registration of O2 and CO2
  • O2 meter 0-2.5% range
  • O2 meter 0-25% range
  • Number of CO2 ranges 1122
  • Measurement and registration of C2 H4
  • Extra sensors (including alarm/output) 5101532
  • CO2 absorption based on chalk
  • CO2 injection
  • C2 H4 injection
  • Aeration based on CO2 value
  • Temperature control
  • Max. number of temperature sensors per room 24610
  • Rending in °F
  • Refrigeration control in cold stores
  • Max. number of relay groups refrigeration 3918
  • Machine room refrigeration controlled
  • Control of refrigeration machine room possible14
  • Relative humidity measurement
  • Control of suction pressure
  • Defrosting sensors
  • Pilot temperature sensor
  • Extras that make the difference
  • Moisture loss measurement and registration
  • Relative humidity measurement
  • Central measurement and registration of NH3
  • Automatic room leakage test
  • CA flex: programmable conditions
  • My Fruit APP

Contact us

Henk Röben

Ramzi Amari
Sales

Niels Remmelink
Sales Manager

contact-plane

Thank you for your message